NICE PSS124 - backup battery for operators with integrated charging


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE PSS124 - backup battery for operators with integrated charging
NICE-PSS124
in stock
€118.94 excluding VAT
€146.29 including VAT

 pcs
Weight
1,40 kg

Description of NICE PSS124 - backup battery for operators with integrated charging

NICE PSS124 backup battery with integrated charging for NICE gate operators with R30 control unit version. Provides backup power in the event of a power outage. Two connecting cables are included. >>Download the manual>>

Backup battery NICE PSS124 is designed for automated sliding gates, swing gates and garage doors with compatible NICE operators. In the event of a power outage, it supplies the operator with the energy needed to move the gate. The battery has integrated charging and recharges continuously while the operator is connected to the mains power supply. A fully charged battery allows approximately 10 operating cycles; the actual number depends on the operator, load, temperature and battery condition.

It is suitable for compatible control units of the R30 generation and is also backward-compatible with the older R10. The package includes two connecting cables for newer and older control units.

Compatible NICE operators
ROBUS RB 250HS/400/500HS/600/1000
ROBUS RBS 400/600/600HS/800
NKSL400
SLIGHT400
RUN1500
ROAD400
TOO 3024/4524
WINGO 2024/3524
HOPP
HYKE/HYKEHS
SFAB 2024/2124
SBAR
SPIDO600
SPIDER 800/800W/1200W
SPIN 23/40
SPYHS
SOON

Installing the backup battery NICE PSS124

1. Disconnect the operator from the mains power supply

2. Connect the battery to the control unit

Select the supplied cable that matches the control unit. Connect and position the battery according to the instructions for the specific operator. Check the connector orientation and wiring in the operator's installation instructions.

3. Check the NICE PSS124 backup battery wiring

Step 3.1 When running on battery power, its LED L1 should be lit red. Also check the control unit's indicator according to its instructions. If the battery is discharged, connect the operator to the mains, let it charge for a few hours, then repeat the test.

Step 3.2 Connect the operator to the mains power supply. LED L1 flashing red at approximately one-second intervals indicates that the battery is charging. Fully open and close the gate while it is powered from the mains.

Step 3.3 Disconnect the operator from the mains power supply. Check that LED L1 is lit red, then fully open and close the gate while it is running on battery power.

Note: When powered by the backup battery, the operator may run at a lower speed even if a higher speed is set.

4. Reconnect the operator to the mains power supply

After a successful test, restore the mains power supply so the battery can recharge continuously.

LED L1 indicators

Indicator Battery status
Two red flashes Powering on
Green flashing at one-second intervals Normal status
Steady red light Operator powered by the battery
Red flashing at one-second intervals Battery charging
Short green flash: on for 0.1 s, off for 3 s Standby power-saving mode
Rapid red flashing every 0.2 s Error

Technical specifications of the NICE PSS124 operator backup battery

Type 24 V battery with integrated charging for backup power to operators
Technology Sealed, maintenance-free lead-acid batteries
Charging and discharge voltage 28 V at maximum charge; 16 V at maximum discharge, at which point the battery disconnects automatically
Output current 6 A nominal; 8 A during the first 3 seconds at startup
Capacity 1.2 Ah – approximately 12 hours in standby mode or 5 minutes at a load of 4 A
Full charging time Approximately 16 hours
Power-saving mode Automatically after charging is complete; standby power consumption less than 0.300 W
Expected service life Approximately 4–6 years depending on operating conditions
Operating temperature −20 °C to +55 °C
Charging temperature −20 °C to +40 °C
Protection rating IP30; for use inside the drive, control unit, or another protected area
Weight 1.396 kg
Package contents Rechargeable backup battery and two connecting cables
Installation and connection See Installation and the included instructions

Battery runtime and service life depend on temperature, current draw, charge level, and battery age.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE PSS124 - backup battery for operators with integrated charging

Product: NICE PSS124 - backup battery for operators with integrated charging
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.