Manual for a 7 to 10 m self-supporting sliding gate

Technical guide · DIY construction · cantilever gate

A practical guide for gates with a clear opening width of 7.0 to 10.0 m: two concrete foundations, cabling, carriages, guide system, operator, wiring, and technical drawings.

Overview of a cantilever sliding gate with clear opening, load-bearing C-profile, carriages, counterbalance, and operator
Main parts of a cantilever sliding gate. Click to open the drawing at full resolution.

Cantilever gate for a 7.0 to 10.0 m clear opening

For a wider opening, the leaf length and weight, counterbalance, load-bearing C-profile, number of carriage rollers, infill, guide system, foundations, and operator must all be coordinated. The guide below starts with the construction work and continues in the order in which the individual components are actually prepared.

What to measure and choose before fabrication

Space

  • clear opening width (ŠP),
  • the side and direction in which the gate slides,
  • clearance for the entire leaf, including the counterbalance,
  • ground levels along the entire travel path.

Structure

  • frame height and infill type,
  • dead weight, infill weight, and wind load,
  • C-profile and carriages designed for the specific load.

Foundations

  • space for two separate foundations,
  • spacing X based on the gate width and carriage type,
  • the position of the mounting plates and conduits.

Controls

  • manual or motorized operation,
  • the location of the operator, photocells, and warning light,
  • the power supply and control method.

1. Concrete foundations and mounting plate locations

The source drawing for gates over 6.5 m uses two separate foundations. The foundation nearer the opening is 1 000 mm long, the second is 1 400 mm long, with a gap X between them. The total length of the assembly is therefore 2 400 + X.

Minimum width of each foundation: 500 mm.
Minimum depth: 800 mm. Recommended distance Y from the wall: 50 to 100 mm.

Plan view showing the two concrete foundations and carriages

Plan view of two concrete foundations for a cantilever gate over 6.5 metres, with dimensions of 1000, X, and 1400 millimetres and mounting plates
Plan view of the foundations, spacing X, and mounting plates. Click to open the full source page.

Concrete foundations – views A and B

Views A and B of two concrete foundations, showing the minimum width of 500 millimetres, depth of 800 millimetres, and mounting plate locations
Views A and B, including ground level, foundation dimensions, and a warning to install the cables before pouring the concrete.

Foundation spacing X based on the clear opening width

Dimension X in millimetres by carriage type

Clear opening width Carriage with 8 rollers Carriage with 10 rollers
7 000 mm 950 mm 850 mm
7 500 mm 1 150 mm 1 050 mm
8 000 mm 1 350 mm 1 250 mm
8 500 mm 1 550 mm 1 450 mm
9 000 mm 1 750 mm 1 650 mm
9 500 mm 2 050 mm 1 950 mm
10 000 mm 2 250 mm 2 150 mm

Bold values correspond to the recommended 10-roller option in the source drawing. Always read dimension X for the carriage actually used.

Mounting plate MD location

Carriage type Dimension Z Mounting plate MD
8 rollers 240 mm 120 × 180 mm
10 rollers 310 mm 120 × 300 mm

The mounting plate holes must be at least Ø 17 mm for M16 threads. Set the top of the foundation according to the required gate clearance above ground and the carriages’ height adjustment range.

2. Preparing cables and conduits before pouring the concrete

Install the conduits and cable outlets before pouring the concrete. The diagram below retains the complete original wiring description, including the power supply, photocells, warning light, antenna cable, and dimension notes.

Recommended cable runs from the source material

Label Connection Cable
I 230 V operator power supply 1 × 3 × 1.5 mm²
II Left photocell 1 × 2 × 0.5 mm²
III Right photocell 1 × 2 × 0.5 mm²
IV Warning light and antenna 1 × 2 × 0.5 mm² + shielded RG58 / 50 Ω coaxial cable
Complete original cable preparation page for NICE Robus RBS 600 and 1000 and RUN 1800 or 2500 operators, including all annotations and the table
Complete cable preparation page, uncropped. Click to open at full resolution.

3. Gate guidance, carriages and ground clearance

The gate leaf must be guided from above or from the side, and the carriages must match the selected C-profile. Height H, measured from the top edge of the foundation to the bottom edge of the C-profile, is determined by the carriages used and their adjustment range.

Top and side guidance for a cantilever gate, carriage height dimensions, and frequently asked questions from the source material
Guidance methods and determining height H. Click to open the original page at full resolution.

Height H by C-profile and number of rollers

C-profile 3 rollers 5 rollers 8 rollers 10 rollers
70 × 70 × 4 mm 78–98 mm 95–115 mm 90–110 mm —
80 × 80 × 5 mm 73–93 mm 90–110 mm 85–105 mm 93–109 mm

Recommended carriages for gates over 6.5 m

Here are practical options for larger C-profiles and heavier loads. Choose the final carriage based on the specific profile, opening width, total weight, infill and gate construction.

View all carriage types

C-profiles for larger cantilever gates

The source drawings use an 80 × 80 × 5 mm profile. More robust systems are also available for heavier loads; choose the specific size only after checking the weight, infill, wind load and compatible carriages.

View all C-profiles

Source overview of CAIS C-profiles for large and oversized gates, including sizes 73 × 61 × 3.5 and 95 × 86 × 5 millimetres
Examples of CAIS profiles for large and oversized gates from the source manual. The selection is not limited to these two sizes.

4. Drive and rack height

The height X of the drive mounting plate depends on carriage height H, C-profile height A, the required clearance Y beneath the rack, and dimension N of the specific drive.

X = H + A + Y + 40 − N
Component Variant Dimension
A – C-profile height 70 × 70 × 4 mm 70 mm
80 × 80 × 5 mm 80 mm
N – drive pinion height ROAD 400 / ROBUS 400 85 mm
ROBUS 600 / ROBUS 1000 92 mm
RUN 1800P 109 mm
Calculation of drive mounting plate and rack height using dimensions H, A, Y and N
Source drawing of drive and rack height, including the table and calculation example.

5. Drive wiring diagrams

RBS600 and RBS800 are part of the new generation of NICE ROBUS drives. The older RB1000 and RUN1800 drives have their own wiring diagrams.

NICE ROBUS RBS600 and NICE ROBUS RBS800

NICE ROBUS RBS600 assembly (D) | NICE ROBUS RBS800 assembly (D)

Wiring diagram for NICE ROBUS RBS600 and RBS800, figure 33 from the installation manual.
Wiring diagram for NICE ROBUS RBS600 and RBS800, figure 33 from the installation manual.

RBS600 / RBS800 installation manual (PDF, page 16)

NICE ROBUS RB1000

NICE ROBUS RB1000 assembly (D)

Wiring diagram for the previous generation NICE ROBUS RB1000, figure 7 from the installation manual.
Wiring diagram for the previous generation NICE ROBUS RB1000, figure 7 from the installation manual.

RB1000 installation manual (PDF, page 12)

NICE RUN1800

NICE RUN1800 assembly (D)

The NICE RUN1800 uses a 230 V AC electric motor, while the ROBUS RBS600/RBS800 and the older RB1000 have a 24 V DC motor. This is the main difference in the motor’s power supply. Both types of operator are connected to the 230 V mains supply.

RUA1 control unit has similar basic functions to the ROBUS. It supports automatic closing, partial opening and connection of BlueBUS photocells. However, the terminal layout and specific wiring differ.

RUN1800 operator dimensions

400 × 255 × 390 mm (length × width × height) according to the manufacturer’s technical table.

NICE RUN1800 dimension drawing, figure 1 from the manufacturer's manual. Dimensions are in millimetres.
NICE RUN1800 dimension drawing, figure 1 from the manufacturer's manual. Dimensions are in millimetres.

The dimension drawing lists 400 × 253 × 387 mm, while the technical table in the same manual lists 400 × 255 × 390 mm.

Dimension drawing in the manual (PDF, page 4) | Technical data (PDF, page 24)

Connecting the RUA1 control unit

The RUN1800 wiring diagram shows the original LUCYB, MOFB and MOSE accessories. It does not show the current kit.

Wiring of the NICE RUN1800 operator’s RUA1 control unit, including the mains cable and cable routing, figures 14 to 16 from the manufacturer’s manual.
Wiring of the NICE RUN1800 operator’s RUA1 control unit, including the mains cable and cable routing, figures 14 to 16 from the manufacturer’s manual.

RUN1800 / RUN2500 installation manual (PDF, page 9)

6. Summary table of dimensions and weights

Applies to the drawings below. The dimensions, net weight and maximum loads apply to the specific assemblies shown in these drawings.

Dimensions and weights for the drawings below

Clear opening Overall gate length Gate dead weight Max. load per metre Max. infill weight
7.0 m 10.0 m 220 kg 50 kg/m 360 kg
7.5 m 10.7 m 250 kg 50 kg/m 385 kg
8.0 m 11.4 m 265 kg 35 kg/m 285 kg
8.5 m 12.1 m 305 kg 35 kg/m 305 kg
9.0 m 12.7 m 320 kg 35 kg/m 320 kg
9.5 m 13.4 m 385 kg 35 kg/m 340 kg
10.0 m 14.1 m 405 kg 25 kg/m 255 kg

Comparing box-section tubes with 2, 3 and 4 mm wall thickness

For the same external dimensions, a box-section tube with a thicker wall weighs more. The following table compares the weight of the frame and bottom reinforcement box-section tubes alone based on the material quantities shown in the drawings. It excludes the 80 × 80 × 5 mm supporting C-profile, infill, fittings and other parts, so these figures are not the net weight of the complete gate shown in the table above.

Approximate weight of box-section tubes based on the material list, excluding the C-profile and infill
Clear opening Gate length 2 mm wall 3 mm wall 4 mm wall
7.0 m 10.0 m 111.8 kg 162.4 kg 208.8 kg
7.5 m 10.7 m 132.9 kg 193.1 kg 248.2 kg
8.0 m 11.4 m 142.3 kg 206.8 kg 265.8 kg
8.5 m 12.1 m 151.8 kg 220.5 kg 283.4 kg
9.0 m 12.7 m 178.0 kg 259.5 kg 335.5 kg
9.5 m 13.4 m 235.0 kg 342.5 kg 442.9 kg
10.0 m 14.1 m 249.2 kg 363.3 kg 469.7 kg

How to choose the frame: Design the gate to be as light as possible while still providing sufficient strength and rigidity for the chosen infill and wind load. Using box-section tubes of a different size or wall thickness will change the frame’s weight and performance. A heavier frame also puts more load on the C-profile and guide rollers. Therefore, the permissible infill weight cannot be increased simply in proportion to the wall thickness.

The maximum load and infill weight values in the first table do not automatically apply to versions with 3 and 4 mm walls. This comparison calculates the material weight, not a new gate load capacity.

Reference data and weight calculation

The outer dimensions of the box sections and the material quantities remain the same in all three columns. Only the wall thickness changes. The quantities are taken from the drawing's bill of materials, not from an exact cutting plan. Offcuts, welds, surface finish and the tolerances of the supplied profiles also affect the weight of the finished frame.

Clear opening 60 × 40 mm box section 80 × 40 mm box section
7.0 m 26 m 10 m
7.5 m 32 m 11 m
8.0 m 34 m 12 m
8.5 m 36 m 13 m
9.0 m 0 m 50 m
9.5 m 0 m 66 m
10.0 m 0 m 70 m

For a clear opening of 9.0 m, the total length of 80 × 40 mm box section used is 13 + 37 m; for 9.5 m, it is 27 + 39 m; and for 10.0 m, it is 29 + 41 m. The total also includes the lower reinforcement shown in the drawing.

External dimensions 2 mm wall 3 mm wall 4 mm wall
60 × 40 mm 2.93 kg/m 4.25 kg/m 5.45 kg/m
80 × 40 mm 3.56 kg/m 5.19 kg/m 6.71 kg/m

Calculation: weight = length of 60 × 40 box section × its weight per metre + length of 80 × 40 box section × its weight per metre. For example, for a 7.0 m clear opening and a 3 mm wall: 26 × 4.25 + 10 × 5.19 = 162.4 kg of box sections.

The linear weights are from the SSAB dimension table, verified on 11. 9. 2026. They are reference values for comparing weights, not confirmation by the manufacturer or of the material grade used in the drawings.

Discrepancies in the drawings: For clear openings of 8.5 m and 10.0 m, the lower box section is labelled differently in the cross-section than in the bill of materials: the section shows a 3 mm wall instead of 2 mm. For 9.5 m and 10.0 m openings, the frame cross-section shows 60 × 40 mm, while the elevation and bill of materials specify 80 × 40 mm. The comparison above explicitly uses the bill of materials. This does not correct the original drawings or their load ratings.

7. Technical drawings for each gate width

Each preview links to the full-resolution image. The summary table above also lists the key dimensions and weights as text; the drawings retain the frame layout, sections, dimensions and carriage load ratings.

Overall length 10,000 mm, frame 7,200 mm, counterbalance 2,800 mm, frame height 1,500 mm, 80 × 80 × 5 mm C-track.

Technical drawing of a cantilever gate with a 7,000 mm clear opening
Drawing for a 7.0 m clear opening – page 7 of the source manual.

Overall length 10,700 mm, frame 7,700 mm, counterbalance 3,000 mm, frame height 1,500 mm, 80 × 80 × 5 mm C-track.

Technical drawing of a cantilever gate with a 7,500 mm clear opening
Drawing for a 7.5 m clear opening – page 8 of the source manual.

Overall length 11,400 mm, frame 8,200 mm, counterbalance 3,200 mm, frame height 1,500 mm, 80 × 80 × 5 mm C-track.

Technical drawing of a cantilever gate with an 8,000 mm clear opening
Drawing for an 8.0 m clear opening – page 9 of the source manual.

Overall length 12,100 mm, frame 8,700 mm, counterbalance 3,400 mm, frame height 1,500 mm, 80 × 80 × 5 mm C-track.

Technical drawing of a cantilever gate with an 8,500 mm clear opening
Drawing for an 8.5 m clear opening – page 10 of the source manual.

Overall length 12,700 mm, frame 9,200 mm, counterbalance 3,500 mm, frame height 1,500 mm, 80 × 80 × 5 mm C-track.

Technical drawing of a cantilever gate with a 9,000 mm clear opening
Drawing for a 9.0 m clear opening – page 11 of the source manual.

Overall length 13,400 mm, frame 9,700 mm, counterbalance 3,700 mm, frame height 1,500 mm, 80 × 80 × 5 mm C-track.

Technical drawing of a cantilever gate with a 9,500 mm clear opening
Drawing for a 9.5 m clear opening – page 12 of the source manual.

Overall length 14,100 mm, frame 10,200 mm, counterbalance 3,900 mm, frame height 1,500 mm, 80 × 80 × 5 mm C-track.

Technical drawing of a cantilever gate with a 10,000 mm clear opening
Drawing for a 10.0 m clear opening – page 13 of the source manual.

8. Frequently asked questions and next steps

Does a gate with a clear opening wider than 6.5 m need two separate foundations?

This manual and its X-spacing table are designed for a pair of foundations as shown in the source drawing. Any change to the design concept must be assessed separately.

Is it enough to select a carriage based on the C-track size?

No. The profile size is only one of the requirements. The total weight, load distribution, counterbalance, infill, wind exposure and operating frequency also matter.

Can I use any drive shown in the diagram?

No. The drive must be selected according to the leaf's weight and length, mechanical resistance, operating frequency and required speed. The wiring diagram does not replace drive sizing.

What should be prepared before pouring the concrete?

The mounting plate positions, all conduit runs, the 230 V supply, and the wiring for photocells, the warning light and any wired controls.

Where can I find the detailed force values for the carriages?

They are shown directly in the technical drawing for each width. The summary table is deliberately simplified to five details needed for an initial overview.

Didn't find the answer? Call us

Contact us. For gates over 6.5 m, we recommend checking the component selection before ordering and pouring the concrete.

Component kits for cantilever gates

CAIS components for large gates

Short on space for a gate?

If a large cantilever gate won't fit on your property, consider another solution. A telescopic gate or other options could be a suitable compromise and help solve the lack of space on your property.

Telescopic cantilever gate

Short on space for a gate? Explore other options

Technical note: For gates of this size, have the final design, foundations, anchoring, infill, wind load and safety features checked against the specific site conditions. Carry out the electrical installation in accordance with the manufacturer's current instructions and applicable regulations.


Prepared by Eng. Ján Kubíček.

Last updated: 16 September 2026.

Back to the beginning of the manual