Wiring the PH-42 magnetic switch

Wiring instructions PH-42 magnetic switch.
The magnetic switch must always be connected to the STOP input, and the gate must be closed (i.e. close the circuit by bringing the magnets together) and proceed as follows:

NICE Road

Connect it to terminals 3-4, then perform a RESET (hold OPEN and CLOSE until all the lights come on), then run the device check again and program the entire motor.

NICE Robus, Run and all models with BlueBUS (except MC800)

Connect it to the STOP terminal, then check the connected devices: press and hold the OPEN and STOP/SET buttons together until LEDs L1+L2 start flashing faster in unison, then release them. Wait until L1+L2 finish flashing; the check is complete.

Control unit MC424LR10

Connect it to terminals 8-9. If there is a jumper across 8-9 (as supplied from the factory), remove it, then move the wires that were connected to terminal 9 to terminal 8.

Control unit MC424L

Connect it to terminals 11-12. If there is a jumper across 11-12 (as supplied from the factory), remove it, then move the wires that were connected to terminal 12 to terminal 11.

Control unit MC800

Connect it to terminals 4-12, then check the connected devices: press and hold the OPEN and STOP/SET buttons together until LEDs L1+L2 start flashing faster in unison, then release them. Wait until L1+L2 finish flashing; the check is complete.

NICE SHEL operator

Connect it to terminals 1-2, then perform a RESET and then check and program the entire motor.

NICE SPINBUS operator

Connect it to the STOP terminal, then check the connected devices: press and hold the OPEN and STOP/SET buttons together until LEDs L1+L2 start flashing faster in unison, then release them. Wait until L1+L2 finish flashing; the check is complete.