NICE PS124 - backup battery for the drive with integrated charging

CLEARANCE SALE


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE PS124 - backup battery for the drive with integrated charging NICE PS124 - backup battery for the drive with integrated charging
NICE-PS124
In stock
€94.85 excluding VAT
€116.66 including VAT

 pcs
Weight
2,00 kg

Description of NICE PS124 - backup battery for the drive with integrated charging

Available replacement!
The NICE PS124 backup battery has been replaced by a newer model NICE PSS124 – backup battery for drives with integrated charging.

Backup battery NICE PS124 is designed for automated sliding gates, swing gates and garage doors powered by NICE motors (ROBUS, POPKIT, SN6031-41, MC424, SBAR). The battery supplies the motor with the electrical power needed to operate if the mains supply to the motor fails. The battery is continuously recharged from the mains. When fully charged, the battery can power approximately 10 gate cycles. of the gate.

Warning!
For sliding gate operators Nice Robus RBS and swing gate operators Nice Toona, S-Fab, M-Fab, L-Fab and B-Fab with control unit version R30 (MC824HR30) a cable adapter is required to connect the backup power supply PS124 or PS324 a cable adapter is required to connect the backup power supply CABLA11.

Installing the backup battery NICE PS124

1. Disconnect the operator's power supply from the mains.

2. Connect the battery to the control unit.

The connectors for connecting to the control unit are not polarised, so it does not matter which way you connect them.

The battery comes with a power cable with two connectors, one narrower and the other wider. Use the wider connector to connect to the control unit and the narrower connector to connect to the battery.

Connecting to a NICE Robus operator:

1. Remove the plastic cover from the battery connector on the control unit. 2. Connect the battery to the connector and place it next to the control unit.
1. Remove the plastic cover from the battery connector 2. Connect the battery to the connector and place it next to the control unit

 

3. Check the connection of the NICE PS124 backup battery as follows:

NICE PS124 operator backup battery

Step 3.1 Check whether the LED L2 on the battery is lit.. If so, the battery is supplying electrical power to the operator. Next, check that the LEDs on the control unit are lit as specified (refer to the manual for the operator). 

If not, the backup battery is probably discharged. Connect the operator to the mains, wait a few hours, then disconnect its power supply again and repeat Step 3.1

Step 3.2 Connect the operator to the mains and check whether the LED L1 on the battery is lit.. If so, the battery is charging correctly. Fully open and close the gate (with the operator connected to the mains). 

Step 3.3 Disconnect the operator from the mains and check whether the LED L2 on the battery is lit (as in Step 3.1). Then fully open and close the gate (with the operator disconnected from the mains and powered only by the battery) to verify that the operator works correctly on battery power alone.

Note: The speed of the operator when powered only by the backup battery may be lower, even if the control unit is programmed for a higher speed.

4. Reconnect the operator to the mains.

Done, everything should now be working correctly. In the event of a power failure, you should still be able to open and close the gate successfully..

Technical specifications for the NICE PS124 operator backup battery

Type 24 V battery with charger to power the gate operator in the event of a power failure 
Technology Electrical energy stored in a hermetically sealed casing (maintenance-free).
Voltage  28 V at full charge
16 V at full discharge (the battery is then disconnected automatically) 
Output current  during operation 6 A
for the first three seconds at start-up 8 A 
Capacity  1.2 Ah, equivalent to approximately 12 hours of powering the operator when idle, or 5 minutes under a 4 A load (approximately 10 cycles)
Full charging time  approximately 16 hours 
Battery life 

approximately 4–6 years, or
over 1,000 cycles at 30% discharge (70% charge), or
over 500 cycles at 50% discharge, or
over 200 cycles at 100% discharge

Operating temperature  

-20°C to +55°C 
Excessively low temperatures reduce battery efficiency; for example, at -10°C, efficiency is approximately 30%
Excessively high temperatures reduce battery life; for example, at +40°C, battery life may be reduced to 2 years

Use in acidic, salty or potentially explosive environments  No
Installation and wiring see Installation
Protection rating  IP30 
Dimensions (W×H×D)  104×143×53 mm 
Weight  1.45 kg 

Backup power supply photo gallery NICE PS124

Front Rear Inside
NICE PS124 drive backup battery, front view NICE PS124 drive backup battery, rear view NICE PS124 drive backup battery, inside view

 

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).